Fujian Lilliput Optoelectronics Technology Co.,Ltd
Home / Products / xsa800 series spectrum analyzer

XSA800 Series Spectrum Analyzer

-  Frequency range 9kHz - 1.5GHz
-  -160 dBm Displayed Average Noise Level (DANL)
-  Phase noise -80 dBc/Hz @1GHz and offset at 10 kHz
-  Total amplitude accuracy <0.7 dB
-  1 Hz minimum resolution bandwidth (RBW)
-  EMI pre-compliance test function (free), EMC test software (options)
-  Optional Tracking Generator (can be upgraded to have TG after purchasing)
-  Waterfall plot graphic, modulation signal quality analysis,
   audio demodulation, ect. multiple general and extended
   test functions.
-  Standard Pass/Fail on-site test and alert function
-  Adopt all-digital intermediate frequency technology
-  Multiple interfaces: USB Host, USB Device, LAN,
   earphone interface, HDMI
-  9-inch LCD, high resolution 1280×800 pixels
Send Inquiry
Product Details






Video
  • XSA800 Spectrum Analyzer Introduction  

Specifications

Frequency
Frequency Range XSA805 9 kHz to 500 MHz
XSA810 9 kHz to 1 GHz
XSA815 9 kHz to 1.5 GHz
Frequency Resolution 1 Hz
Reference frequency aging rate < 1 ppm/year
Frequency Span
Span Range 0 Hz, 100 Hz to max frequency of instrument
Span Uncertainty ± span / (sweep points-1)
SSB Phase Noise(20 to 30, fc = 500 MHz)
Carrier Offset 10 kHz < -80 dBc/Hz
100 kHz < -100 dBc/Hz
1 MHz < -115 dBc/Hz
Bandwidth
Resolution Bandwidth(-3 dB) 1 Hz to 1 MHz, in 1-3-5-10 sequence
Resolution Bandwidth (-6 dB) (EMI) 200 Hz, 9 kHz, 120 kHz, 1 MHz
RBW Accuracy < 5% typical
Resolution Filter Shape Factor (60 dB : 3 dB) < 5 typical
Video
Bandwidth (-3 dB)
10 Hz to 1 MHz, in 1-3-5-10 sequence
Amplitude and level
Amplitude measurement range DANL to +10 dBm, 100 kHz to 10 MHz, Preamp Off
DANL to +20 dBm, fc ≥ 10 MHz, Preamp Off
Reference Level -80 dBm to +30 dBm, 0.01 dB by step
Preamp 20 dB, nominal, 100 kHz to 1.5 GHz
Input Attenuator 0 to 40 dB, 1 dB by step
Display Average Noise Level (Input attenuation = 0 dB, RBW = VBW = 100 Hz, sample detector, trace average ≥ 50, 20 to 30, input impedance = 50 Ω)
Preamp Off 9 kHz to 1 MHz -95 dBm (Typical), <-88 dBm
1 MHz to 500 MHz -140 dBm (Typical), <-130dBm
XSA810 500 MHz to 1 GHz
XSA815 500 MHz to 1.5 GHz -138 dBm (Typical), <-128 dBm
Preamp On 100 kHz to 1 MHz -135 dBm (Typical), <-128 dBm
1 MHz to 500 MHz -160 dBm (Typical), <-150 dBm
XSA810 500 MHz to 1 GHz
XSA815 500 MHz to 1.5 GHz -158 dBm (Typical), <-148 dBm
Level Display
Trace detectors positive-peak, negative-peak, normal, sample, RMS, voltage average, quasi-peak
Trace functions clear write, max hold, min hold, average, view, blank, trace math
Units of level axis dBm, dBμW, dBpW, dBmV, dBμV, W, V
Frequency response
(fc ≥ 100 kHz, 20 to 30,30% to 70% relative humidity, input attenuation=10 dB, reference frequency= 50 MHz)
Preamp Off <0.7 dB
Preamp On <1.0 dB
Difference and Accuracy
Uncertainty fc = 50 MHz, peak detector, preamplifier off, attenuation = 10 dB, input signal level = -10 dBm, 20℃ to 30℃
< 0.4 dB
Level Measurement Uncertainty
Level measurement uncertainty 95% confidence level, S/N > 20 dB, RBW = VBW = 1 kHz, preamplifier off, attenuation = 10 dB, -50 dBm < input level ≤ 0 dBm, fc > 10 MHz, 20℃ to 30℃
< 0.7 dB
Tracking Generator (optional)
Frequency Range  XSA805 100 kHz to 500 MHz
XSA810 100 kHz to 1 GHz
XSA815 100 kHz to 1.5 GHz
Output power
level range
-40 dBm to 0 dBm
Output level resolution 1 dB
Output flatness Relative to 50 MHz
± 3 dB
Tracking generator spurious Harmonic spurious -30 dBc (Tracking generator output power -10 dBm)
Non-harmonic spurious -40 dBc (Tracking generator output power -10 dBm)
Tracking generator to input terminal isolation -60 dB (Tracking generator output power 0 dBm)
Interface
USB Host, USB Device, LAN, earphone interface, HDMI
Display
9-inch TFT LCD, 1280 x 800 pixels
Appearance
Dimensions 375 mm (W) × 185 mm (H) × 120 mm (D)
Weight Approx. 3.7 kg (main device)

Support
Accessories

The accessories subject to final delivery.

  • Power Cord
  • Quick Guide
  • USB Cable
  • N-N Cable (optional)
  • N-SMA Cable (optional)
  • SMA-SMA Cable (optional)
  • SMA Adaptor (optional)
  • Near Field Probe (optional)
  • N-SMA Adaptor
  • N-BNC Adaptor
Inquiry
* Your Name :
Company Name :
* E-mail :
* Phone:
* Country :
   Address :
Product Serial No. :
* Comment :
* Confirmation Code :
Refresh
 

We utilize cookies on in.owon.com to enhance functionalities and optimize performance, as well as to facilitate the delivery of personalized advertising aligned with your preferences. Please click 'I Accept' to proceed. For comprehensive information on how OWON manages cookies or to customize your cookie preferences, please click Read More

I Refuse